Cecomp Electronics Ctp1B+1Kgcmg-Cd, Ctp1B Digital Pressure Gauge

USD 483.90

In stock

Cecomp Electronics, CTP1B±1KGCMG-CD, CTP1B Battery Powered Digital Pressure Gauge with 1 Button Operation and Calibration Data, –1.03-1 Kilograms/cm2, –14.7-14.2 PSI Power-Up Press and hold the front button for approximately 1 second



Description


Attempting to zero the gauge with pressure greater than approximately 3 of full-scale pressure or vacuum applied will result in an error condition, and the display will alternately indicate Err 0 and the actual measured pressure

Be sure the gauge port is exposed to normal atmospheric pressure and no pressure is applied

Display back lighting can be turned on by momentarily pressing the power button whenever the gauge is on

If the gauge is set up without auto shutoff on/off operation it will stay on until manually shut off or until the batteries are depleted

Options CD - Calibration data 5 test points and date Red rubber boot White LED backlight All metal case Port reinforcement Coated circuit boards Features plusmn 0.1 Test Gauge Accuracy in Most Ranges Ultra-Ruggedized Design 316L Stainless Steel Wetted Parts Selectable Units and Auto Shutoff Times White LED Display Backlight Min/Max Memory

Power-Up with Zero Absolute reference gauges do not use the zero feature since they read atmospheric pressure under normal conditions

Press and hold the front button

Release the button and the full-scale range in the selected units are indicated, the display is tested again, then the actual pressure and units are displayed

Shut-Down To shut off the gauge manually at any time, press and hold the button until the display indicates OFF about 5 seconds and then release

The auto shutoff and backlight if equipped timers are reset whenever the button is pressed and released

The back lighting will turn on for 1 minute and then automatically shut off

The button can be pressed to keep the gauge on

The display back lighting will not be apparent under bright lighting conditions

The display is tested and then oooo is displayed

The display is tested, the default full-scale range is indicated, the full-scale range in the selected units are indicated, the display is tested again, then the actual pressure and units are displayed

The gauge is now zeroed

The gauge must be powered down to reset the error condition

The zeroing function is only activated at each power-up and the stored zero correction is erased when the gauge is shut off

This also restarts the auto shutoff timer

Turn gauge off when not in use to conserve battery life

When an auto shutoff timer is used, the display indicates OFF five seconds prior to auto shutoff